Macrotherm Flat Travelling Cables for Elevators

Flat Traveling Cables, made up of electrolytic copper conductor, which provide an electric connection between an Elevator / dumbwaiter car, and a fixed electrical outlet in the hoist way.

Call: 04027710180, 04027713859, 04066335524 +919393000066,  Whats App: +919393000066 +919908952786

Available at Reliable Engineering Products India Pvt Ltd, Ranigunj, Secunderabad.

MACROTHERM FLAT TRAVELLING CABLES - H05VVH6-F

MACROTHERM FLAT TRAVELLING CABLES - H05VVH6-F Reliable Engineering Products India Pvt Ltd Ranigunj Secunderabad

Applications: Elevator Suspension Cable for Internal and Panoramic Elevators

Applicable Standard: IEC 60227-6, EN 50214

Construction

CONDUCTOR – Flexible bright annealed bare copper conductor Class 5, manufactured using 99.97% pure electrolytic grade copper, with more than 100% conductivity, as per IEC 60228

INSULATION – Specially formulated PVC with a blend of Elastomer, for continuous flexing operation, meeting the requirement of Type D as per IEC 60227-2

CORE IDENTIFICATION – Black insulated cores printed with numerals in white & one Y/G for Ground

GROUPING – Structured parallel lay with each group having a rip cord & Steel Rope strength member on request – for high rise application

OUTER SHEATH – Specially formulated PVC with a blend of Elastomer, for continuous flexing operation, meeting the requirement of Type ST 3 as per IEC 60227-2, in black color

H05VVH6-F MECHANICAL PROPERTIES

FREE SUSPENSION LENGTH: 45Mts. (Max.)

TRAVELLLING HEIGHT: 80 Meters (Max.)

RUNNING SPEED: 4 Mts. /Second (Max.)

ACCELERATION: < 0.8 Meters / Second2

OPERATING TEMPERATURE:

Mobile Utilization – 5°C ~ +70 °C

Fixed Utilization – 10°C ~ +70 °C

BENDING RADIUS: Cable Thickness x 10 (Min.)

RECOMMENDED LOOP DIAMETER:

Cable Thickness t < 5 mm; t x 70 (min)

Cable Thickness t < 5~9 mm; t x 65 (min)

Cable Thickness t > 9 mm; t x 60 (min)

According to table, Tolerance -50 mm, +100 mm

IR CONSTANT at 270: 36.7 M Ω Km

FLAME RETARDANCE: IEC 60332-1

SHEATH MARKING:

MM/YY MACROTHERM < H05VVH6-F > nGx.xx sequential metric marking

H05VVH6-F ELECTRICAL PROPERTIES

RATED VOLTAGE:-

≤ 1 mm2 300/500 V

≥ 1.5 mm2 450/750 V

TEST VOLTAGE:-

≤ 1 mm2 – 2 kV (rms) / 15 minutes

≥ 1.5 mm2 – 2.5 kV (rms) / 15 minutes

IR CONSTANT at 270:- 36.7 M Ω Km

0.75 mm2 - Bare Cu Cond., Special elastomeric blend PVC Insulated
1.50 mm2 Bare Cu Cond., Special elastomeric blend PVC Insulated

MACROTHERM FLAT TRAVELLING CABLES - H05VVD3H6-F

Call: 04027710180, 04027713859, 04066335524 +919393000066,  Whats App: +919393000066 +919908952786

Available at Reliable Engineering Products India Pvt Ltd, Ranigunj, Secunderabad.

FLAT TRAVELLING CABLES WITHOUT STRAIN BEARING MEMBERS - H05VVD3H6-F Reliable Engineering Products India Pvt Ltd Ranigunj Secunderabad
FLAT TRAVELLING CABLES WITHOUT STRAIN BEARING MEMBERS - H05VVD3H6-F DIAGRAM Reliable Engineering Products India Pvt Ltd Ranigunj Secunderabad

Construction

CONDUCTOR: Flexible bright annealed bare copper conductor Class 5, manufactured using 99.97% pure electrolytic grade copper, with more than 100% conductivity, as per IEC 60228

INSULATION: Specially formulated PVC with a blend of Elastomer, for continuous flexing operation, meeting the requirement of Type D as per IEC 60227-2

CORE IDENTIFICATION: Black insulated cores printed with numerals in white & one Y/G for Ground

STRAIN-BEARING MEMBERS: Steel Rope

GROUPING: Structured parallel lay with each group having a rip cord & Steel Rope strength member

OUTER SHEATH: Specially formulated PVC with a blend of Elastomer, for continuous flexing operation, meeting the requirement of Type ST 5 as per IEC 60227-2, in black color

H05VVD3H6-F​ MECHANICAL PROPERTIES

FREE SUSPENSION LENGTH: 120 Mts. (Max.)

TRAVELLLING HEIGHT: 150 Meters (Max.)

RUNNING SPEED: 6.3 Meters. / Second (Max.)

ACCELERATION: < 0.8 Meters / Second2

OPERATING TEMPERATURE:

  • Mobile Utilization – 5°C ~ +70 °C
  • Fixed Utilization – 10°C ~ +70 °C

BENDING RADIUS: Cable Thickness x 10

RECOMMENDED LOOP DIAMETER: According to table, Tolerance -50 mm, +100 mm

IR CONSTANT at 270: 36.7 M Ω Km

FLAME RETARDANCE: IEC 60332-1

SHEATH MARKING:

MM/YY MACROTHERM H05VVD3H6-F nGx.xx sequential metric marking

H05VVD3H6-F​ ELECTRICAL PROPERTIES

RATED VOLTAGE:

≤ 1 mm2 300/500 V

≥ 1.5 mm2 450/750 V

TEST VOLTAGE:

≤ 1 mm2 – 2 kV (rms) / 15 minutes

≥ 1.5 mm2 – 2.5 kV (rms) / 15 minutes

2.50 mm2 Bare Cu Cond., Special elastomeric blend PVC Insulated
4 ~ 25 mm2 Bare Cu Cond., Special elastomeric blend PVC Insulated